Strategies in Trauma and Limb Reconstruction

Register      Login

VOLUME 18 , ISSUE 1 ( January-April, 2023 ) > List of Articles

Original Article

Circular External Fixator Removal in the Outpatient Clinic Using Regional Anaesthesia: A Pilot Study of a Novel Approach

Luke Michael Williams, Giles Stamps, Helen Peak, Shiv Kumar Singh, Nicholas Peterson

Keywords : External fixator, Frame removal, Limb reconstruction, Relative stability, Regional anaesthesia, Ultrasound-guided nerve blocks

Citation Information : Williams LM, Stamps G, Peak H, Singh SK, Peterson N. Circular External Fixator Removal in the Outpatient Clinic Using Regional Anaesthesia: A Pilot Study of a Novel Approach. 2023; 18 (1):7-11.

DOI: 10.5005/jp-journals-10080-1582

License: CC BY-NC-SA 4.0

Published Online: 31-05-2023

Copyright Statement:  Copyright © 2023; The Author(s).


Abstract

Introduction: External fixator (EF) devices are commonly used in the management of complex skeletal trauma, as well as in elective limb reconstruction surgery for the management of congenital and acquired pathology. The subsequent removal of an EF is commonly performed under general anaesthesia in an operating theatre. This practice is resource-intensive and limits the amount of time available for other surgical cases in the operating theatre. We aimed to assess the use of regional anaesthesia as an alternative method of analgesia to facilitate the EF removal in an outpatient setting. Design and methods: This prospective case series evaluated the first 50 consecutive cases of EF removal in the outpatient clinic between 10/06/22 and 03/02/23. Regional anaesthesia using ultrasound-guided blockade of peripheral nerves was administered using 1% lidocaine due to its rapid onset and short half-life. Patients were assessed for additional analgesia requirements and then were asked to evaluate their experience and perceived pain using the visual analogue scale (VAS). Results: Fifty patients were included in the study. The mean age was 46.8 years (range 21–85 years). About 54% of the patients were male patients (N = 27). Post-procedure, all patients indicated positive satisfaction ratings, each participant responded as either ‘satisfied’ (N = 6), ‘very satisfied’ (N = 24) or ‘highly satisfied’ (N = 20). In addition, 90% of the participants reported that they would opt for this method of EF removal again in future. The VAS for pain immediately following completion of the procedure was low, with a mean score of 0.36 (range 0–4), where a score of 0 = ‘No pain’, and 10 = ‘worst pain possible’. The median score was 0. Conclusion: We present the first description of outpatient EF removal using regional anaesthesia, with a prospective case series of 50 fully conscious patients from whom the EF was removed. This novel technique is likely to be cost-effective, reproducible, and safe. This technique reduces the burden of EF removal from an operating list and also improves the patient's experience when compared with other forms of conscious sedation. By eliminating the use of Entonox and methoxyflurane for sedation and analgesia, this technique also demonstrates a method of improving environmental sustainability.


HTML PDF Share
  1. Hohmann E, Birkholtz F, Glatt V, et al. The “Road to Union” protocol for the reconstruction of isolated complex high-energy tibial trauma. Injury 2017;48(6):1211–1216. DOI: 10.1016/j.injury.2017.03.018.
  2. Fernando PLN, Abeygunawardane A, Wijesinghe PCI, et al. An engineering review of external fixators. Medical Engineering and Physics. 2021;98: 91–103. DOI: 10.1016/j.medengphy.2021.11.002.
  3. Debuka E, Peterson N, Fischer B, et al. Penthrox® (Methoxyflurane) as an analgesic for removal of circular external fixators and minor procedures during the COVID-19 emergency. Orthopaedic Proceedings. vol 103-B. Presentation at BLRS Annual Scientific Meeting.
  4. Wyssusek K, Chan KL, Eames J, et al. Greenhouse gas reduction in anaesthesia practice: a departmental environmental strategy. BMJ Open Quality. 2022;11:e001867. DOI: 10.1136/bmjoq-2022-001867.
  5. Klein AA, Meek T, Allcock E, et al. Guideline: Recommendations for standards of monitoring during anaesthesia and recovery 2021. Assoc Anaesth 2021;1–12. DOI: 10.1111/anae.15501.
  6. Garra G, Singer AJ, Taira BR, et al. Validation of the Wong-Baker FACES pain rating scale in pediatric emergency department patients. Acad Emerg Med. 2010;17(1):50–54. DOI: 10.1111/j.1553-2712.2009.00620.x.
  7. Sadekar V, Watts AT, Moulder E, et al. Is a staged reloading protocol effective to time the removal of circular frames. Bone Jt Open 2022;3(5):359–366. DOI: 10.1302/2633-1462.35.BJO-2021-0179.R1.
  8. Gray Stephens CEB, Dias A, Skinner E, et al. Penthrox enables quicker management of fractures, dislocations and more: learning lessons from expedited care of trauma patients during the COVID-19 pandemic. Ann R Coll Surg Engl 2021;1–6. DOI: 10.1308/rcsann.2021.0340.
  9. Coffey F, Wright J, Hartshorn S, et al. STOP!: a randomised, double-blind, placebo-controlled study of the efficacy and safety of methoxyflurane for the treatment of acute pain. Emerg Med J. 2014;31(8):613–618. DOI: 10.1136/emermed-2013-202909.
  10. Eager MM, Nolan GS, Tonks K, et al. Inhaled methoxyflurane (Penthrox) for analgesia in trauma: a systematic review protocol. System Rev 2021;10(1):47. DOI: 10.1186/s13643-021-01600-0.
  11. Raju P, Hickman J. Sustainability: medical gases. Royal Coll Anaesthetists. E-Learning for Anaesthesia. 2020. Version 1.
  12. Jeng CL, Torillo TM, Rosenblatt MA. Complications of peripheral nerve blocks. Br J Anaesthesia. 2010;105:i97–i107. DOI: 10.1093/bja/aeq273.
  13. Battaloglu E, Bose D. The history of Ilizarov. Trauma. 2013;15:257–262. DOI: 10.1177/1460408613486743.
  14. Nanchahal J, Nayagam S, Khan U, et al. Standards for the management of open fractures of the lower limb. Br Assoc Plast Reconstr Aesthet Surg 2009;1–97.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.