Complications occurring during surgery are not uncommon and may lead to abandoning of the procedure. Discussed here is one such case where complication was managed and optimal surgical treatment was carried out as was planned preoperatively.
Case report
A 72-year-old male planned for posterior dynamic stabilization (PDS) broke his spinous process during surgery without any undue stress or force. Spinous process was reconstructed and PDS done as planned with improvisation on table.
Conclusion
A broken spinous process during surgery was successfully reconstructed and stabilized with two Coflex dynamic devices at either end.
How to cite this article
Pawar SG, Prasad A, Dhar A, Ramani PS. Broken Spinous Process and Posterior Dynamic Stabilization. J Spinal Surg 2017;4(1):26-29.
Surgery for lumbar spinal stenosis. Attempted meta-analysis of the literature. Spine (Phila Pa 1976) 1992 Jan;17(1):1-8.
The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. J Spinal Disord 1993 Dec;6(6):461-472.
Pedicle screw fixation in spinal disorders: a European view. Eur Spine J 1997;6(1):2-18.
Minimum 5-year results of degenerative spondylolisthesis treated with decompression and instrumented posterior fusion. Spine (Phila Pa 1976) 1999 Aug;24(16):1721-1727.
Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis. Spine (Phila Pa 1976) 2006 Feb;31(4):442-449.
A 10-year follow-up evaluation of lumbar spine fusion with pedicle screw fixation. Spine (Phila Pa 1976) 2003 Jul;28(13):1390-1395.
Device implanted complications of Coflex interspinous dynamic stabilization. Zhonghua Wai Ke Za Zhi 2012 Sep;50(9):782-787.
Device related complications of the Coflex interspinous process implant for the lumbar spine. Chin Med J (Engl) 2013 Jul;126(13):2517-2522.
Complications in degenerative lumbar disease treated with a dynamic interspinous spacer (Coflex). Int Orthop 2013 Nov;37(11):2199-2204..
Summary of Safety & Effectiveness Data (SSED). 2012 Oct 17, PMA P110008. Pp. 1-42. Available from: http://www.accessdata.fda.gov/cdrh_docs/pdf11/P110008b.pdf
Insertion loads of the X STOP interspinous process distraction system designed to treat neurogenic intermittent claudication. Eur Spine J 2006 Jun;15(6):908-912.
Spinous process strength. Spine (Phila Pa 1976) 2000 Feb;25(3):319-323.