The Journal of Spinal Surgery

Register      Login

VOLUME 4 , ISSUE 1 ( January-March, 2017 ) > List of Articles

RESEARCH ARTICLE

C1-C2 Posterior Cervical Fixation by a Harms Technique Modification

Ioannis Siasios, Kunal Vakharia, Joseph M Kowalski, Vassilios G Dimopoulos, John Pollina

Citation Information : Siasios I, Vakharia K, Kowalski JM, Dimopoulos VG, Pollina J. C1-C2 Posterior Cervical Fixation by a Harms Technique Modification. J Spinal Surg 2017; 4 (1):14-18.

DOI: 10.5005/jp-journals-10039-1118

Published Online: 01-12-2012

Copyright Statement:  Copyright © 2017; The Author(s).


Abstract

Introduction

The unique anatomy of the upper cervical spine in conjunction with its supportive role in the axial stabilization and rotatory function of the head increases the surgical risk and associated complications for corrective surgeries performed in this spinal region. C1-C2 posterior fixation is indicated in the occurrence of instability at the craniocervical junction; and it can be performed by specific surgical techniques, such as the Harms and Magerl techniques. In this technical note, the authors present a simplified modification of the Harms technique that increases the accuracy of screw placement in the lateral mass of the C1 vertebra and in the pedicle of the C2 vertebra. This modification provides a secure path for screw placement by obtaining fluoroscopic images of K-wires inserted in the lateral masses of C1 and the pedicles of C2 as in the original technique. According to this technique, a pin driver is used to guide a K-wire through the initially marked entry point to the lateral mass of C1. After fluoroscopic confirmation of the optimal position of the guidewire, a cannulated hand drill is placed over the guidewire. A pilot hole is drilled in the same trajectory for the screw placement under fluoroscopic control. Then the guidewire and the hand drill are removed and an appropriately sized 3.5 mm polyaxial screw is placed with a hand drill under confirmation of the correct position with anteroposterior and lateral fluoroscopy. The same procedure is followed for the placement of the C2 pedicle screws. Then, a small rod is placed and secured within the polyaxial screw heads of the C1 and C2 screws bilaterally. Decortication of the spinous processes of the involved vertebrae and the occiput is the final step before closure of the fascia, cervical muscle layer, subcutaneous tissue, and skin.

How to cite this article

Siasios I, Vakharia K, Kowalski JM, Dimopoulos VG, Pollina J. C1-C2 Posterior Cervical Fixation by a Harms Technique Modification. J Spinal Surg 2017;4(1):14-18.


PDF Share
  1. Vertebral artery anomalies at the craniovertebral junction in the US population. Spine (Phila Pa 1976) 2014 Aug;39(18):E1053-E1057.
  2. Vertebral artery anomalies at the craniovertebral junction: a case report and review of the literature. Evid Based Spine Care J 2014 Oct;5(2):121-125.
  3. Clinically relevant complications related to posterior atlanto-axial fixation in atlanto-axial instability and their management. Clin Neurol Neurosurg 2014 Aug;123:131-135.
  4. Late complication of surgically treated atlantoaxial instability: occipital bone erosion induced by protruded fixed titanium rod: a case report. J Chiropr Med 2014 Dec;13(4):278-281.
  5. Modified C1 lateral mass screw insertion using a high entry point to avoid postoperative occipital neuralgia. J Clin Neurosci 2013 Jan;20(1):162-167.
  6. C1-C2 posterior fixation: indications, technique, and results. Orthop Clin North Am 2012 Jan;43(1):11-18, vii.
  7. C1-C2 posterior fixation: are 4 screws better than 2? Neurosurgery 2012 Sep;71(Suppl 1 Operative):86-95.
  8. IV. Traumatic lesions of the atlas and axis. Ann Surg 1910 Feb;51(2):193-207.
  9. Skeletal traction in the treatment of fractures and dislocations of the cervical spine. Ann Surg 1937 Oct;106(4):770-776.
  10. Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am 1978 Apr;60(3):279-284.
  11. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 2001 Nov;26(22):2467-2471.
  12. ; Seemann P. Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A, editors. Cervical spine. New York: Springer-Verlag; 1985. p. 322-327.
  13. Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine (Phila Pa 1976) 2002 Aug;27(16):1724-1732.
  14. The interspinous method of posterior atlantoaxial arthrodesis. J Neurosurg 1991 Feb;74(2):190-198.
  15. Posterior atlantoaxial fusion. A new internal fixation device. Spine (Phila Pa 1976) 1994 Jun;19(12):1397-1401.
  16. Spine fusion for atlanto-axial instability. J Bone Joint Surg Am 1976 Apr;58(3):400-407.
  17. Atlanto-axial arthrodesis. J Bone Joint Surg Br 1973 Aug;55(3):482-489.
  18. Atlantoaxial fusion with posterior double wire fixation. Spine (Phila Pa 1976) 1992 Nov;17(11):1409-1413.
  19. Posterior atlantoaxial arthrodesis. A simplified method. Spine (Phila Pa 1976) 1991 Aug;16(8):878-880.
  20. Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 1994;129(1-2):47-53.
  21. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 2004 Apr;17(2):158-162.
  22. Transoral fusion for high cervical fractures. J Bone Joint Surg Br 1990 Jan;72(1):76-79.
  23. Lateral atlantoaxial arthrodesis. Orthop Clin North Am 1978 Oct;9(4):1101-1114.
  24. Biomechanical evaluation of four different posterior atlantoaxial fixation techniques. Spine (Phila Pa 1976) 1992 May;17(5):480-490.
  25. Outcome comparison of atlantoaxial fusion with transarticular screws and screw-rod constructs: meta-analysis and review of literature. J Spinal Disord Tech 2014 Feb;27(1):11-28.
  26. Clinical and radiological comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation. J Clin Neurosci 2010 Jul;17(7):886-892.
  27. Atlantoaxial fusion with transarticular screws: meta-analysis and review of the literature. World Neurosurg 2013 Nov;80(5):627-641.
  28. Comparison of screw malposition and vertebral artery injury of C2 pedicle and transarticular screws: meta-analysis and review of the literature. J Spinal Disord Tech 2014 Aug;27(6):305-315.
  29. Atlantoaxial fixation using the polyaxial screw-rod system. Eur Spine J 2007 Apr;16(4):479-484.
  30. C1-C2 stabilization by Harms arthrodesis: indications, technique, complications and outcomes in a prospective 26-case series. Orthop Traumatol Surg Res 2014 Apr;100(2):221-227.
  31. Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy. Spine (Phila Pa 1976) 2006 Mar;31(5):536-540; discussion 41.
  32. CT-guided C2 pedicle screw placement for treatment of unstable Hangman's fractures. Spine (Phila Pa 1976) 2014 May.
  33. Computed tomography-guided C2 pedicle screw placement for treatment of unstable hangman fractures. Spine (Phila Pa 1976) 2014 Aug;39(18):E1058-E1065.
  34. Computer-assisted C1-C2 transarticular screw fixation “Magerl Technique” for atlantoaxial instability. Asian Spine J 2012 Sep;6(3):168-177.
  35. Surgical management of symptomatic os odontoideum with posterior screw fixation performed using the Magerl and harms techniques with intraoperative 3-dimensional fluoroscopy-based navigation. Spine (Phila Pa 1976) 2012 Oct;37(21):1839-1846.
  36. Isocentric C-arm three-dimensional navigation versus conventional C-arm assisted C1-C2 transarticular screw fixation for atlantoaxial instability. Arch Orthop Trauma Surg 2015 Aug;135(8):1083-1092.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.