Indian Journal of Respiratory Care

IJRC Email      Register      Login

VOLUME 10 , ISSUE 2 ( May-August, 2021 ) > List of Articles

Original Article

Self-reported Continuous Positive Airway Pressure Device Compliance of Patients with Obstructive Sleep Apnoea Syndrome

Fatih Uzer, Ummuhan Okur, Aykut Cilli

Keywords : Adherence, compliance, continuous positive airway pressure, obstructive sleep apnea syndrome, positional, rapid eye movement

Citation Information : Uzer F, Okur U, Cilli A. Self-reported Continuous Positive Airway Pressure Device Compliance of Patients with Obstructive Sleep Apnoea Syndrome. Indian J Respir Care 2021; 10 (2):221-225.

DOI: 10.4103/ijrc.ijrc_135_20

License: CC BY-NC-SA 4.0

Published Online: 06-12-2022

Copyright Statement:  Copyright © 2021; Indian Journal of Respiratory Care.


Abstract

Introduction: Patients with obstructive sleep apnoea syndrome (OSAS) are often prescribed the use of continuous positive airway pressure (CPAP) devices to overcome obstruction during sleep. We aimed at assessing the adherence rates to CPAP therapy in two clinical subtypes of OSAS. Patients and Methods: Patients diagnosed with positional or rapid eye movement related OSAS using polysomnography were included. Patients were contacted by telephone calls to collect data. Inclusion criteria were age >18 years, a total apnea-hypopnea index (AHI) >5, and a physician recommendation to initiate therapy with a CPAP device. Patients were excluded if they had known neurological disorders, were unwilling to answer all questions and had no recommendation to use CPAP therapy. Results: A total of 286 patients, 99 females (34.6%) and 187 males (65.4%), with a mean age of 56.5 ± 11.3 years were included. There were 134 (46.9%) CPAP users and 152 (53.1%) CPAP nonusers. Reasons for not using the CPAP device included unwillingness to use the device (n = 73, 48%), reduced patient comfort due to noise, hose, or air pressure (n = 31, 20.3%), reimbursement problems (n = 38, 25%), and reasons such as recovery or operation (n = 10, 6.5%). Age, duration of use/months, number of nights per week during which the device was used and the mean number of hours per night were not significantly different between OSAS types (P > 0.05), while the mean AHI and body mass index were significantly different between OSAS types (P < 0.05). Conclusion: A significant proportion of OSAS patients do not use CPAP devices due to various reasons. Adherence to CPAP therapy was not significantly different between groups.


HTML PDF Share
  1. Epstein LJ, Kristo D, Strollo PJ Jr., Friedman N, Malhotra A, Patil SP, et al. Clinical guideline for the evaluation, management and long-term care of obstructive sleep apnea in adults. J Clin Sleep Med 2009;5:263-76.
  2. Fanfulla F, Grassi M, Taurino AE, D'Artavilla Lupo N, Trentin R. The relationship of daytime hypoxemia and nocturnal hypoxia in obstructive sleep apnea syndrome. Sleep 2008;31:249-55.
  3. Demir A, Ursavaş A, Tana Aslan A, Gulbay B, Ciftci B, Cuhadaroğlu C, et al. The report of Turkish thoracic society on the diagnosis and treatment of obstructive sleep apnea syndromes. Turk Thorac J. 2012;13 (Suppl 1):1–73.
  4. Alves C, Caminha JM, da Silva AM, Mendonça D. Compliance to continuous positive airway pressure therapy in a group of Portuguese patients with obstructive sleep apnea syndrome. Sleep Breath 2012;16:555-62.
  5. Weaver TE, Sawyer AM. Adherence to continuous positive airway pressure treatment for obstructive sleep apnoea: Implications for future interventions. Indian J Med Res 2010;131:245-58.
  6. Weaver TE, Grunstein RR. Adherence to continuous positive airway pressure therapy: The challenge to effective treatment. Proc Am Thorac Soc 2008;5:173-8.
  7. Rotenberg BW, Murariu D, Pang KP. Trends in CPAP adherence over twenty years of data collection: A flattened curve. J Otolaryngol Head Neck Surg 2016;45:43-52.
  8. Berry RB, Budhiraja R, Gottlieb DJ, Gozal D, Iber C, Kapur VK, et al. Rules for scoring respiratory events in sleep: Update of the 2007 AASM manual for the scoring of sleep and associated events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine. J Clin Sleep Med 2012;8:597-619.
  9. Roecklein KA, Schumacher JA, Gabriele JM, Fagan C, Baran AS, Richert AC. Personalized feedback to improve CPAP adherence in obstructive sleep apnea. Behav Sleep Med 2010;8:105-12.
  10. To KW, Chan WC, Choo KL, Lam WK, Wong KK, Hui DS. A randomized cross-over study of auto-continuous positive airway pressure versus fixed-continuous positive airway pressure in patients with obstructive sleep apnoea. Respirology 2008;13:79-86.
  11. Krieger J. Long-term compliance with nasal continuous positive airway pressure (CPAP) in obstructive sleep apnea patients and nonapneic snorers. Sleep 1992;15:6.
  12. Sanders MH, Gruendl CA, Rogers RM. Patient compliance with nasal CPAP therapy for sleep apnea. Chest 1986;90:330-3.
  13. Uzer F, Toptaş AB, Okur U, Bozkurt S, Dogrul E, Turhan M, et al. Comparison of positional ad rapid eye movement – dependent sleep apnea syndromes. Ann Thorac Med 2018;13:42-7.
  14. Joo MJ, Herdegen JJ. Sleep apnea in an urban public hospital: Assessment of severity and treatment adherence. J Clin Sleep Med 2007;3:285-8.
  15. Campbell A, Neill A, Lory R. Ethnicity and socioeconomic status predict initial continuous positive airway pressure compliance in New Zealand adults with obstructive sleep apnoea. Intern Med J 2012;42:95-101.
  16. Kribbs NB, Pack AI, Kline LR, Smith PL, Schwartz AR, Schubert NM, et al. Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnea. Am Rev Respir Dis 1993;147:887-95.
  17. Schwab RJ, Badr SM, Epstein LJ, Gay PC, Gozal D, Kohler M, et al. An official American Thoracic Society statement: Continuous positive airway pressure adherence tracking systems. The optimal monitoring strategies and outcome measures in adults. Am J Respir Crit Care Med 2013;188:613-20.
  18. Collard P, Pieters T, Aubert G, Delguste P, Rodenstein DO. Compliance with nasal CPAP in obstructive sleep apnea patients. Sleep Med Rev 1997;1:33-44.
  19. Budhiraja R, Parthasarathy S, Drake CL, Roth T, Sharief I, Budhiraja P, et al. Early CPAP use identifies subsequent adherence to CPAP therapy. Sleep 2007;30:320-4.
  20. Villar I, Izuel M, Carrizo S, Vicente E, Marin JM. Medication adherence and persistence in severe obstructive sleep apnea. Sleep 2009;32:623-8.
  21. BaHammam AS, Alassiri SS, Al-Adab AH, Alsadhan IM, Altheyab AM, Alrayes AH, et al. Long-term compliance with continuous positive airway pressure in Saudi patients with obstructive sleep apnea. A prospective cohort study. Saudi Med J 2015;36:911-9.
  22. Engleman HM, Martin SE, Douglas NJ. Compliance with CPAP therapy in patients with the sleep apnoea/hypopnoea syndrome. Thorax 1994;49:263-6.
  23. Wild MR, Engleman HM, Douglas NJ, Espie CA. Can psychological factors help us to determine adherence to CPAP? A prospective study. Eur Respir J 2004;24:461-5.
  24. Gagnadoux F, Le Vaillant M, Goupil F, Pigeanne T, Chollet S, Masson P, et al. Influence of marital status and employment status on long-term adherence with continuous positive airway pressure in sleep apnea patients. PLoS One 2011;6:95-101.
  25. Yetkin O, Kunter E, Gunen H. CPAP compliance in patients with obstructive sleep apnea syndrome. Sleep Breath 2008;12:365-7.
  26. Sawyer AM, Gooneratne NS, Marcus CL, Ofer D, Richards KC, Weaver TE. A systematic review of CPAP adherence across age groups: Clinical and empiric insights for developing CPAP adherence interventions. Sleep Med Rev 2011;15:343-56.
  27. Rauscher H, Formanek D, Popp W, Zwick H. Self-reported vs measured compliance with nasal CPAP for obstructive sleep apnea. Chest 1993;103:1675-80.
  28. Hui DS, Choy DK, Li TS, Ko FW, Wong KK, Chan JK, et al. Determinants of continuous positive airway pressure compliance in a group of Chinese patients with obstructive sleep apnea. Chest 2001;120:170-6.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.