Nowadays, miniscrew anchorage system is encouraged to obtain better results in orthodontic treatment. This system also brings emergency complications like fractures during insertion of these miniscrews. According to protocol flap-raising technique, a periodontist should be consulted during retrieval of the fractured miniscrew. Here, we propose a new technique that can retrieve the fractured implant with uneventful healing by the vibration of micromotor blunt burs or ultrasonic scaler tips with reinsertion in 7 days.

Keywords: Flapless vibration technique, Microimplant fracture, Retrieval of implant.

How to cite this article: Rath SK, Swain CS, Panda SM. Fractured Miniscrew Retrieval through Flapless Vibration Technique: A Mini Review and Case Report. Int J Oral Implantol Clin Res 2017;8(1):31-33.