JAYPEE JOURNALS
International Scientific Journals from Jaypee
Subscriber's Login
Home Instructions Editorial Board Current Issue Pubmed Archives Subscription Contact Us
The Journal of Contemporary Dental Practice
Abstract
 
 

ABSTRACT

Aim: This study analyzed the effect of the dimensions of the flute and shank in the first 4 mm of instrument tips on the deformation and dimensional changes of reciprocating instruments after root canal shaping (RCS).

Materials and methods: The reciprocating instruments used were ReciprocR R25, R40, and R50; WaveOneR Small, Primary, and Large; and UniconeR #20, #25, and #40. Scanning electron microscopy images of the first 4 mm of the tip were acquired at 30~ magnification before and after simulated curved root canals were shaped. Each instrument was used only once. The images were transferred to the AxioVisionR software to measure the flute area (μm2), shank area (μm2), flute length (μm), and crosssectional diameter (μm). Studentfs t test for paired samples was used to compare differences before and after RCS, and analysis of variance followed by the Tukey test, to compare differences between instruments of similar sizes. The instruments were classified according to deformations after RCS.

Results: ReciprocR instruments had larger flutes and smaller shanks. The ReciprocR R40 had significant differences in crosssectional diameter at 0.5 mm from the tip. ReciprocR had no plastic deformations. UniconeR #20 instruments had significant differences in cross-sectional diameter at 1.5 and 3.0 mm from the tip, and #25 instruments had differences at 1.5 and 3.0 mm and in length of the second and third flutes. One #20 and three #40 instruments had plastic deformations. The differences in length of the first and fourth flutes of WaveOne® Primary and in cross-sectional diameter at 2.0 mm from the tip of WaveOne® Large were significant. Two of three WaveOne® Large instruments had plastic deformations.

Conclusion: Reciproc® instruments had greater flute areas and lengths and smaller shanks than Unicone® and WaveOne® instruments of similar sizes. Reciproc® instruments had a greater flute-to-shank ratio. WaveOne® instruments had the lowest flute-to-shank ratio. Unicone® instruments had the most plastic deformations. Instruments with larger flutes and smaller shanks had fewer plastic deformations after curved RCS. Clinical significance: The knowledge of mechanical behavior before choosing the endodontic instrument may avoid fracture, regardless of the clinical condition, and it is essential to the success of root canal treatment.

Keywords: Endodontic instruments, Flute, Laboratory research, Plastic deformation, Reciprocating instruments, Root canal shaping.

How to cite this article: Sampaio FC, Brito APP, Veloso HHP, Alencar AHG, Decurcio DA, Figueiredo JAP, Estrela C. Flute and Shank Dimensions of Reciprocating Instruments before and after Simulated Root Canal shaping. J Contemp Dent Pract 2017;18(3):198-204.

Source of support: CAPES

Conflict of interest: None

 
 
logo
© Jaypee Brothers Medical Publishers (P) Ltd.